Generators
Easy handling- No cogging torque, maintenance-free!
NdFeBo permanent magnets – these are the strongest permanent magnets currently available. No cogging torque, maintenance-free!
To ensure long, maintenance-free service of the generators in the ANTARIS wind turbine, the copper winding in the stator is configured to meet insulation class F (155° C).
As the repeller is attached directly on the generator shaft, BRAUN Windturbines GmbH employs special ball bearings to reliably take up the axial and radial forces that are produced.
The copper winding is fitted exclusively by hand. Despite progressive automation in other generator components (CNC production), hand-fitted windings continue to be the preferred option for good reason. This ensures that the insulating materials used undergo full inspection, meeting the stringent demands BRAUN Windturbines GmbH places on quality.
Incidentally, this also applies to setting up the magnetic field in the rotor (moving part of the generator). Here too, the magnets are fitted by hand, with polarity subsequently being checked. To ensure that the magnets do not become detached, they are glued in the grooved rotor with high-strength adhesive. The entire rotor is additionally potted in impregnating resin. In short, quality workmanship "Made in Germany"!
The generators are used as battery chargers, for grid-connected operation or for heating up heater elements (wind-powered heating).
Power output ranges from 1.5 kW to 6.5 kW (14.0 kW max. for brief periods). Appropriate control systems for applications of this type are also available (see picture gallery).
If you wish to drive the generator with a diesel or similar engine (combined heat and power system), it may be possible to dispense with any gearing as a result of speed adjustment on the generator side.
Weight: 50 kg
Base anchoring
Shaft diameter: 28 mm etc.
Housing material: aluminium
Cooling: surface, fan wheel
Direction of rotation: either
Type: 10-24-pole (depending on size); protection rating: IP55
Efficiency: 90-95 %
This generator series is designed for wind and water turbine systems! Efficiency remains virtually constant throughout the speed range. The generators are of non-cogging design so that the wing energy system can start up easily at low wind speeds. They are predominantly used for feeding energy from wind energy systems into the grid and are geared to the Windy Boys from SMA (Windy Boy 1100, 1700, 2500, 3000, 3300, 3800) in terms of their power output range. Rotor diameter should be 2.50 m – 4.10 m.
Needless to say, we can also manufacture generators delivering higher power output levels and with a greater number of poles (for low speeds) – just ask us!
Generators for wind energy systems
Application areas
Battery charger, 24 VDC or 48 VDC/2100 watts
Speeds: 125 rpm (off-load voltage)
31 VDC / 650 rpm, 2100 watts
(other speeds also possible on request)
Grid-connected operation 400 VDC / 230 VAC / 2300 watts
Speeds: 130 rpm / 130 VDC (off-load voltage)
650 rpm / 375 VDC and 2350 watts for grid feed-in
(grid feed-in with Windy Boy 1100/1700)
Operation for heating systems
520 VDC / 2500 W (4300 W max.)
520 VDC / 3500 W (5500 W max.)
Generators for combined heat and power systems with grid in-feed
Power output classes: 2500 watts
Speeds: 200 rpm / 250 VDC (off-load voltage)
830 rpm / 590 VDC and 2500 watts for grid feed-in
(grid feed-in with Windy Boy 2500)
The drive motor should have a power output of 3-5 kW, at 2200 rpm max.
Thermal load is approx. 6 kW!
Power output classes: 3500 watts
Speeds: 200 rpm / 200 VDC (off-load voltage)
850 rpm / 590 VDC and 3500 watts for grid feed-in
(grid feed-in with Windy Boy 3800)
The drive motor should have a power output of 4-6 kW, at 2200 rpm max.
Thermal load is approx. 8 kW.
The ideal supplementary power source for heating a family home!
Power output tables
Datenblatt Generator 24V.pdf (131.0 kB)
Datenblatt Generator 48V.pdf (131.0 kB)
Datenblatt Generator 2500Watt-1100WB.pdf (134.9 kB)
Datenblatt Generator 2500Watt-1700WB.pdf (134.8 kB)
We can also overhaul or rewind your generator for you.
Permanent-magnet generator with Windy Boy 6000
or two Windy Boys 1700 for grid-connected operation.
The non-cogging 16-pole generator is used in conjunction with low-speed water or wind turbines.
Speed range with two Windy Boys 1700)
Idling speed
100 VDC at 97 rpm
160 VDC at 147 rpm
320 VDC at 299 rpm
Operating speed
224 VDC at 287 rpm and 1200 watts
350 VDC at 390 rpm and 3000 watts
Technical specifications for both designs:
- Weight: 57 kg
- 6-point base anchoring
- Shaft diameter: 48 mm, Size: 132
- special bearings and bearing shields
- Housing material: aluminium
- Cooling: surface, fan wheel
- Direction of rotation: either
- Type: 10-16 pole;
- Efficiency: 91%
- Protection rating: IP56
- Magnetic field temperature-resistant up to 155°C
- Winding isolation class F (180°C)



This link shows how a generator works!
http://www.zum.de/dwu/depotan/apem112.htm
Here you can see a overload test from the alternator for the ANTARIS 5.5 kW. The alternator is producing 12.0 kW without vibration.
That is high quality work "Made in Germany"!